4-6
Section 4 Electrical System
OS 255
Cockpit Switch Panel
Fishbox Pump
The fishbox macerator switch is momentary
switch that activates the overboard macera-
tor pump for the fishbox; protected by a cir-
cuit breaker on the MDP.
Cabin switch panels
The following are controlled by the cabin
switches.
Electric Head (Optional)
Operates the electric head. Refer to the
head owner's manual for operating instruc-
tions.
Head Macerator
Activates the macerator for the holding tank
overboard discharge. This breaker remains
in the "OFF" position except when pumping
out the holding tank.
Refer to the Interior Equipment chapter for
additional information on the operation of the
overboard macerator discharge system.
Miscellaneous Electrical Components
Cabin Lights
Lighting is controlled by a switch located
adjacent to the companionway door and by
switches on the cabin lights.
12-Volt Receptacle
Power is provided to the 12-volt accessory
receptacle by a breaker located on the
breaker panel.
4.4 Electrical System
Maintenance
12-Volt DC Electrical System
Maintenance
At least semi-annually, spray all exposed
electrical components behind the helm and
in the plugs, with a silicon-based protector.
Remove exterior light fixture bulbs and coat
the metal contact areas with a non-water
soluble lubricant such as petroleum jelly or
silicone grease. Spray the sockets with a sil-
icon-based protector. Do not to get any oil or
petroleum jelly on the glass portion of the
bulbs, as this will cause the bulb to overheat
and burn out.
Check all below deck wiring to ensure
proper support, and that the insulation is
sound, and there are no loose or corroded
terminals. Thoroughly clean corroded termi-
nals with sandpaper or replace them. Secure
and spray with a metal and electrical protec-
tor. Inspect all engine wiring.
Check the electrolyte level in the batteries
regularly and add distilled water as neces-
sary. Check electrolyte level more often if
frequently charged by a battery charger. The
correct fluid level in the cells is usually
approximately 1/4 to 1/2 inch above the
plates. If fluid is needed, fill to the proper
level with distilled water. Do not over fill!
! CAUTION
Halogen lighting contains a filament
bulb that generates intense heat, is
pressurized and could shatter if
scratched or damaged. Protect glass
halogen-cycle bulbs from contact with
liquids when operating.
! CAUTION
Always use a bulb with the same rat-
ing as the original when replacing
light bulbs in marine light fixtures.
Using a different bulb can cause the
fixture to overheat and melt or short
circuit.